Paralleling outputs
Select tip  

Vicor’s Maxi, Mini and Micro modules support paralleling of identical converters to expand the output power. A PR signal is communicated to all modules within the parallel array to synchronize switching frequency. Current sharing is inherent due to the matched power trains of the converters, even under conditions of dynamic loading. In a parallel array, the PR pin function allows only one module to be the Driver; all other modules will automatically become Boosters. Care should be taken by choosing a proper PR-connection. The following application note discusses different ways to connect the PR interface.

For a group of four converters or more in parallel and for fault tolerant redundant arrays, Vicor’s PR transformer is required. Connecting the SC pin to –SENSE will configure a module as a Booster. This can be helpful where arrays are being variably trimmed as only the Driver module needs to be adjusted.

When constructing arrays all SENSE pins must be connected to a common point. The Micro modules do not incorporate remote sense functionality. Please contact Vicor’s applications engineers before using Micros in redundant or parallel arrays. Make sure that the output pins never become open circuit from the output bus as damage to the module may occur.

Paralleling outputs
  • The +Out and -Out power buses should be designed to minimise and balance parasitic impedance from each module output to the load.

  • The +Sense pins should be tied to the same point on the +Out power bus; the -Sense pins should be tied to the same point on the -Out power bus.

  • At the discretion of the power system designer, a subset of all modules within an may be configured as Boosters by shorting SC to ­S.

  • OR'ing diodes may be inserted in series with the +OUT pins of each module to provide module output fault tolerance.

Figure 1 – N+1 module array output connections (Maxi and Mini)

Paralleling outputs

Figure 2 – ORing diodes connections (Maxi and Mini)

Paralleling outputs
  • The +Out and -Out power buses should be designed to minimise and balance parasitic impedance from each module output to the load.

  • At the discretion of the power system designer, a subset of all modules within an array may be configured as Boosters by shorting SC to -Out.

  • Do not use output OR'ing diodes with parallel arrays of MicroMods

Figure 3– Parallel module array output connections (Micro)

This tip is taken from Insight, Vicor Europe's quarterly newsletter.
Sign up now to ensure that you do not miss an issue.

Vicor in Europe
Select your country - find the contact
button
Vicor Resource Library

Have you tried our online resource library? We offer hundreds of
datasheets, application notes, design guides, and more.

Prototype Orders
  • Find out about Vicor Express Ordering
  • Austria:
    0800 20 37 27

  • Benelux:
    00 800 419 419 20
  • Denmark:
    00800 8426 7000
  • France:
    0800 419 419
  • Germany:
    0800 018 29 18
  • Italy:
    800 899 677
  • UK:
    0800 980 8427
  • Spain:
    900 993 998
  • Not in your area? Questions?
    We will call you, simply let us know where you are.